A Comparative
Theoretical Study on Gamma-Ray Shielding Parameters of Organic NLO Compounds
within the 0.1MeV–20 MeV Energy Range Utilizing Multiple Modeling and
Simulation Tools
In this
study, a systematic theoretical and computational evaluation is performed to
investigate the radiation-shielding efficiency of two organic non-linear
optical (NLO) compounds: 3-[1-(2-phenylhydrazinylidene)ethyl]-2H-chromen-2-one (C17H14N2O2)
and 4-nitrophenyl hydrazone (C13H11N3O2).
The investigation was conducted across a broad photon energy spectrum (0.1 MeV
to 20 MeV) using a multi-platform simulation to ensure the highest degree of
precision and reliability. Specifically, the shielding effectiveness was
estimated by Monte Carlo simulations in Geant4, and the results were validated
against computational
tools including EpiXS, XCOM and Phy-X/PSD. Computational modeling
and simulation effectively streamline candidate selection for specific
shielding applications, serving as a time and cost-efficient alternative to
laboratory experiments. Fundamental parameters, including the mass attenuation
coefficient
[1] V.V. Awasarmol, D.K. Gaikwad, S.S.
Obaid, P.P. Pawar, Gamma radiation studies on organic nonlinear optical
materials in the energy range 122–1330 keV, Proc. Natl. Acad. Sci., India,
Sect. A Phys. Sci. 90 (2020), pp. 839–844. https://doi.org/10.1007/s40010-019-00636-1
[2] M.R. Suresh Kumar, H.J. Ravindra, S.M.
Dharmaprakash, Synthesis, crystal growth and characterization of glycine
lithium sulphate. J. Cryst. Growth. 306 (2007), pp. 361–365. https://doi.org/10.1016/j.jcrysgro.2007.05.015
[3] D.S. Chemla, J. Zyss, Nonlinear optical properties of organic molecules and crystals, vol 1. Academic, Orland, 1987.
[4] V.V. Awasarmol, D.K. Gaikwad, S.D. Raut, P.P. Pawar, Gamma ray interaction studies of organic nonlinear optical materials in the energy range 122 keV–1330 keV, Results Phys. 7 (2017), pp. 272–279. http://dx.doi.org/10.1016/j.rinp.2016.12.017
[5] V.V. Awasarmol, D.K. Gaikwad , S.D. Raut , P.P. Pawar, Photon interaction study of organic nonlinear optical materials in the energy range 122 keV to 1330 keV, Radiat. Phys. Chem. 130 (2017), pp.343-350. https://doi.org/10.1016/j.radphyschem.2016.09.012
[6] V.V. Awasarmol, P.P. Pawar, M.B. Solunke, Effective atomic numbers and effective electron densities of inorganic nonlinear optical materials in the energy range 356 keV -1330 keV, Int. J. Tech. Res. Sci. 2 (2017), pp.26-29.
[7] M.S. Al?Buriahi, V.P. Singh, Halil Arslan, V.V. Awasarmol, B.T. Tonguc, Gamma?ray attenuation properties of some NLO materials: potential use in dosimetry, Radiat. Environ. Biophys. 59 (2020), pp.145–150. https://doi.org/10.1007/s00411-019-00824-y
[8] S. Bhadauria, M. Das, S. Saxena, R. Prasad, P. Sen, R. Dwivedi, Recent progress in non-linear optical material, syntheses, characterization and geometry optimization of dicinnamalacetone. Arch. Phys. Res. 2 (2011), pp.36–44.
[9] Vishal Vishwanath Awasarmol, Gamma ray attenuation parameters of inorganic nonlinear optical materials in the energy range 122 keV to 1330 keV, Indian J. Pure Appl. Phys. 55 (2017), pp. 65-72.
[10] H.
Baltas, S. Celik, U. Cevik, E. Yamaz, Measurements of mass attenuation
coefficient and effective atomic number for MgB2 superconductor using
X-ray energies, Radiat. Meas. 42 (2007), pp.55–60. https://doi.org/10.1016/j.radmeas.2006.08.005
[11] S.S.
Shaikh, S.B. Borul, S.S. Khan, A study on the gamma-ray attenuation coefficient
parameters for potassium carbonate, Int. J. Eng. Technol. Manag. Sci. 7 (2023),
pp.79-86. https://doi.org/10.46647/ijetms.2023.v07i03.011
[12] Z.
Aygün, M. Aygün, Radiation shielding potentials of Hf0.5Mo0.5NbTiZrCrx
(X=0.1,0.3,0.5) refractory high entropy alloys by EPIXS, Rahva J. Tech. Soc.
Stud. 3 (2023), pp. 83-95.
[13]
Z. Aygun, Study on radiation shielding characteristics of refractory high
entropy alloys by EpiXS code, Acta Phys. Pol. A, 143 (2023), pp.66-74. https://doi.org/10.12693/APhysPolA.143.66
[14] V.P. Singh, S.P. Shirmardi, M.E. Medhat, N.M. Badiger, Determination of mass attenuation coefficient for some polymers using Monte Carlo simulation, Vacuum, 119 (2015), pp. 284-288. https://doi.org/10.1016/j.vacuum.2015.06.006
[15] C.V. More, H. Alavian , P.P. Pawar, Evaluation of gamma-ray attenuation characteristics of some thermoplastic polymers: Experimental, WinXCom and MCNPX studies, J. Non-Cryst. Solids, 546 (2020), https://doi.org/10.1016/j.jnoncrysol.2020.120277
[16] G.A. Urfa, T. Wianto, T.N. Manik, A.V. Nasrulloh, Study of alternative shielding material for gamma radiation using Monte Carlo simulation, J. Teknol. Reaktor Nuklir, 25 (2023), pp. 101–106. https://doi.org/ 10.55981/tdm.2023.6925
[17] I. Han, L. Demir, Mass attenuation coefficient, effective atomic and electron number of Ti and Ni alloy, Radiat. Meas. 44 (2009), PP.289–294. https://doi.org/10.1016/j.radmeas.2009.03.010
[18] I. Han, L. Demir, M. Sahin, Determination of mass attenuation coefficient, effective atomic number and electron number for some natural minerals. Radiat. Phys. Chem. 78 (2009), pp. 760–764. https://doi.org/10.1016/j.radphyschem.2009.03.077
[19] M.E. Medhat, V.P. Singh, Mass attenuation coefficients of composite materials by Geant4, XCOM and experimental data: comparative study. Radiat. Eff. Defects Solids, 169 (2014), pp. 800–807. http://dx.doi.org/10.1080/10420150.2014.950264
[20] K. Alsafi , D. Abdullah Aloraini , H.M. Almutairi , S.A.M. Issa ,
H.M.H. Zakaly, K.S. Shaaban, Comprehensive study of optical, thermal, and
gamma-ray shielding properties of B2O3–SiO2–BeO–
MgO–La2O3, glasses, Opt. Mater. 150 (2024). https://doi.org/10.1016/j.optmat.2024.115298
[21] H.A. Ali , I.I. Turki , G.Sh. Al-Obaidy , J.M. Rzaij, Evaluating the gamma-ray attenuation characteristics of various radioactive sources using binary and ternary polymer blends, J. Compos. Adv. Mater. 35 (2025), pp. 935-945. https://doi.org/10.18280/rcma.350513
[22] S.G. Uzun1, H. Ero?lu, B. Bilmez, M.C. Tufan, M. Gürbüz, B.C. Turan, Gamma attenuation properties of SrTiO3 doped with Rb and Y, Cumhuriyet Sci. J., 46 (2025), pp. 949-956. https://doi.org/10.17776/csj.1739508
[23] Z.A. Alrowaili, E.O. Echeweozo, S. Alomairy, A. Hammoud, C. Sriwunkum, N.S. Alsaiari, I. Boukhris , M.S. Al-Buriahi, Gamma attenuation, buildup factors, and radiation shielding performance of CaO-borosilicate glasses , J. Radiat. Res. Appl. Sci. 18 (2025). https://doi.org/10.1016/j.jrras.2024.101221
[24] M.W. Aladailah, M.W. Marashdeh, H. Akhdar , O.L. Tashlykov, Al-Tamimi Walaa and A.A. Ghazal, Investigation of the gamma and neutron radiation properties of strontium bismuth borate glasses doped with neodymium ions using the Geant4 simulation toolkit and EpiXS software, Radiat. Eff. Defects Solids, 178 (2023), pp. 485–499. https://doi.org/10.1080/10420150.2022.2153250
[25] M.I. Sayyed, O.I. Olarinoye, M. Elsafi, Assessment of gamma-radiation attenuation characteristics of Bi2O3–B2O3–SiO2–Na2O glasses using Geant4 simulation code, Eur. Phys. J. Plus, 136 (2021). https://doi.org/10.1140/epjp/s13360-021-01492-y
[26] A.A. SKIN, Evaluation of the gamma and neutron shielding properties of 64TeO2 + 15ZnO + (20 ? x)CdO + xBaO + 1V2O5 glass system using Geant4 simulation and Phy-X database software, Pramana – J. Phys. 94 (2020). https://doi.org/10.1007/s12043-020-01972-3
[27] F.H. Alkallas, A.G. Trabelsi, S. Elaissi, T.A. Alrebdi, L. Abu El Maati, F. B. M. Ahmed, M. M. Mahasen, M. Ahmad, M. M. Soraya, Investigation of the gamma photon shielding in Se–Te–Ag chalcogenide glasses using the Phy-X/ PSD software, Cogent Eng. 9 (2022). https://doi.org/10.1080/23311916.2022.2116829
[28] H. Akhdar, Theoretical investigation of gamma- and neutron-shielding properties of polysulfone (PSU) polymer material using Geant4, Polymers, 14 (2022). https://doi.org/10.3390/polym14163374
[29] R.R. Bhosale, C.V. More, D.K. Gaikwad, P.P. Pawar, M.N. Rode, Radiation shielding and gamma ray attenuation properties of some polymers, Nucl. Technol. Radiat. Prot. 32 (2017), pp. 288-293. http://doi.org/10.2298/NTRP1703288B
[30] S.R. Manohara, S.M. Hanagodimath, L. Gerward, The effective atomic numbers of some biomolecules calculated by two methods: A comparative study, Med. Phys., Vol. 36 (2009), pp.137-141. https://doi.org/10.1118/1.3030952
[31] V. Zebardast, A.A. Saray, Experimental and simulation study of shielding features of polyester/ HgO composites against photons using GEANT4 and MCNP codes, Sci. Rep. 15 (2025). https://doi.org/10.1038/s41598-025-17942-x
[32] J.H. Hubbell, S.M. Seltzer, Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest. Natl. Inst. Stand. Phys. Lab, NISTIR; (1995). https://dx.doi.org/10.18434/T4D01F
[33] J.H. Hubbell, Photon mass attenuation and energy absorption coefficients. Int. J. Appl. Radiat. Isot. 33 (1982). pp.1269–1290. https://doi.org/10.1016/0020-708X(82)90248-4
[34] M.J.
Berger, J.H. Hubbell, (XCOM) Photon cross section on a personal computer.
National Bureau of Standards, Gaithersburg, MD, NBSIR 87-3597, Jul. 1987.
[35] L.
Gerward, N. Guilbert, K.B. Jensen, H. Levring, X-ray absorption in matter,
reengineering XCOM, Radiat. Phys. Chem. 60 (2001), pp. 23–24. https://doi.org/10.1016/S0969-806X(00)00324-8
[36]
T.K. Kumar, K.V. Reddy, Effective atomic numbers for materials of dosimetric
interest. Radiat. Phys. Chem. 50 (1997), pp. 545-553. https://doi.org/10.1016/S0969-806X(97)00089-3
[37] C.T. Chantler,
Theoretical form factor, attenuation, and scattering tabulation for Z = 1–92
from E = 1–10 eV to E = 0.4–1.0 MeV. J. Phys. Chem. Ref. Data, 24 (1995), pp.
71- 643. https://doi.org/10.1063/1.555974
[38]
Shivaramu, V. Ramprasath, Effective atomic numbers for photon energy absorption
and energy dependence of some thermoluminescent dosimetric compounds. Nucl.
Instrum. Methods Phys. Res., Sect. B, 168 (2000), pp. 294-304. https://doi.org/10.1016/S0168-583X(99)01100-3
[39] S. Gowda, S.
Krishnaveni, T. Yashoda, T.K. Umesh, R. Gowda, Photon mass attenuation
coefficients, effective atomic numbers and electron densities of some
thermoluminescent dosimetric compounds. Pramana, 63 (2004), pp. 529-541. https://doi.org/10.1007/BF02704481
[40] S. Agostinelli, J. Allison, K. Amako,
J. Apostolakis, H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee, G. Barrand,
et al. Geant4—A simulation toolkit. Nucl. Instrum. Methods Phys. Res., Sect. A,
506 (2003), pp. 250–303. https://doi.org/10.1016/S0168-9002(03)01368-8
[41] C.T. Chantler, Detailed tabulation of
atomic form factors, photoelectric absorption and scattering cross section, and
mass attenuation coefficients in the vicinity of absorption edges in the soft
X-ray (Z = 30–36, Z = 60–89, E = 0.1 keV–10 keV), addressing convergence issues
of earlier work. J. Phys. Chem. Ref. Data, 29 (2000), pp. 597-801. https://doi.org/10.1063/1.1321055
[42] V.P. Singh, M.E. Medhat, N.M. Badiger,
Photon attenuation coefficients of thermoluminescent dosimetric materials by
Geant4 toolkit, XCOM program and experimental data: a comparison study. Ann.
Nucl. Energy, 68 (2014), PP. 96-100. https://doi.org/10.1016/j.anucene.2014.01.011
[43]
Shivaramu, Effective atomic numbers for photon energy absorption and photon
attenuation of tissues from human organs. Med. Dosim. 27 (2002), PP.1-9. https://doi.org/10.1016/S0958-3947(01)00078-4
[44] Z-G. Yin, H-Y. Qian, J. Jia,
N. Zhou, L-Q. Feng, (E)-1-Benzylidene-2-(4-nitrophenyl)hydrazine, Acta
Crystallogr., Sect. E 62 (2006), pp. o4913–o4914. https://doi:10.1107/S1600536806040372